Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement

Feature: Corrsion Resistance
Size: Optional
Material: Cocrmo+UHMWPE
Application: Knee Replacement
Transport Package: Sterilized Packing
Specification: Customized
Samples:
US$ 880/Unit 1 Unit(Min.Order)
| Request Sample
Corrosion resistance
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Customized
Origin
Tianjin Province

Product Description



                  Tibial Bearing Primary TKA Total Knee Artificial Replacement High Flexion


Features

Femoral condylar:
1. High flexion design;
2. Optimized patellofemoral articular design;
3. Almost custom-made component size, 2mm increments in A/P;
4. Proportional posterior condyles allow for greater contact area in deep flexion;
5. Mirror polished surface reduces wear and debris post-operatively;
6. Soften intercondylar notch reduces post wear in flexion;
7. Cam extension provides increase resistance to dislocation in deep flexion.
8. All femoral condyle match with tibial tray perfectly, close to customization

Tibial Tray:
1. Narrowed cruciate fins preserve more bone stock;
2. High polished surface minimizes back wear of bearing;
3. Almost custom-made sizes.

Tibial bearing:
1. Design for high flexion;
2. Allows for proper axial rotation and hyperextension of knee;
3. Interchangeable for femoral components of all sizes;
4. 1:1 tibial/femoral coronal congruency increases contact area in high flexion and axial rotation;
5. Patellar tendon relief facilitates increased range of motion, protecting patellar tendon in deep flexion;
6. Rounded post geometry minimizes forces on the post due to rotation of the femur.

Technical parameters:
1. Material: CoCrMo+Imported PE
2. 145°high flexion
3. Post Stabilized(PS)
4. Mirror Polishing
5. Specification: Femoral: 1#-9#, Tibial: 1#-7#, Pad: 1/2/4/6#

Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial ReplacementManufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement
Advantages
1. Rounded Sagittal Profile
Two distinct femoral designs:Anatomic (box-like) femoral profile and swept-back (rounder) femoral profile.Rounded sagittal profile, as founded in the SK1 knee,allows for greater range of motion and may be more forgiving to the retinaculum by not over tensioning the soft tissues.


2. Deeperlswept-back Trochlear Groove
The trochlear groove is a critical design feature for patella performance. Translation of the trochlear groove posteriorly in the femur has shown to resist patella crepitus and clunk. The SK1 trochlear groove has been designed to sweep back posteriorly for better patellar performance.


Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement

                                                                                     Anatomic(Green) vs.Swept-back Sagittal Profile (Gray)


3. Extended Trochlear Groove
The trochlear groove has been lengthened to further support the patella in deep flexion and provide more support of the quadriceps tendon.The junction of the trochlear groove and PS box articulates with the quadriceps tendon at 105-120 degrees of flexion.

Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement


4. Wider Proximal Trochlear Goove
Patellar capture during flexion must be balanced with the need for less patellar constraint in extension.The trochlear floor of the SK1 knee has been widened to reduce the constraining forces in extension. The patella track provides a 6.5 degree valgus angulation and a 2mm lateralized trochlear groove."Valgus angulation has been shown to reduce the patellar shear stresses."


Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial ReplacementExcept the wider trochlear groove,SK1 knee system provides a set of plan to accords with the biomechanics of patello femoral joint,including loosening of femoral retinaculum, more lateral trochlear and clinically proven good effect circular patella. To sum up the above total features, the wider proximal trochlear groove offers excellent patellar tracking (within 0-15 degrees of valgus) regardless of the patient's Q-angle.The loosening of femoral retinaculum will decrease effectively the tensile force of soft tissue to reduce the potential need to the loosening of lateral accessory ligament.


Application steps

Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial ReplacementManufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement

Specifications 

Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial ReplacementManufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial ReplacementManufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement


About us
Guangzhou sailong additive manufacturing co., ltd  which is a high-tech enterprise led by core members of the technical team.  Dr. qiangbing Wang, deputy director of the state key laboratory of porous metal materials. 
The company is mainly engaged in the design, development, production and sales of spherical metal powder, powder equipment, metal 3d printing parts, porous metal materials and titanium alloy product, widely used in additive manufacturing, laser cladding, surface coating, electronic product and other fields.

Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement

Delivery
Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement
Certificates 
Manufacturer Rsk Femoral Condyle Revision Tka Total Knee Artificial Replacement
 FAQ

Q1. How about your delivery time?
A: Generally, it will take 8 to 15 days after receiving your advance payment. The specific delivery time depends on  the items and the quantity of your order.

Q2. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery.


Q3: What materials are these products?
A: CoCrMo and PE.

Q4: What's your payment method ?
A: TT , L/C or Western Union.

Q5: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them no matter           where they come from.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
12
Year of Establishment
2018-10-25